Omniscia Platypus Finance Audit
Static Analysis
Static Analysis
The execution of our static analysis toolkit identified 282 potential issues within the codebase of which 279 were ruled out to be false positives or negligible findings.
The remaining 3 issues were validated and, along with 2 compilation errors, grouped and formalized into the 4 exhibits that follow:
ID | Severity | Addressed | Title |
---|---|---|---|
MPS-01S | Informational | No | Enumerable Set Optimization |
MPS-02S | Informational | Yes | Test Imports |
VPP-01S | Minor | Yes | Inexistent Protection Against Reentrancy |
VPP-02S | Informational | Yes | Unused Function Inputs |