Omniscia Badai Tech Audit

Static Analysis

Static Analysis

The execution of our static analysis toolkit identified 27 potential issues within the codebase of which 16 were ruled out to be false positives or negligible findings.

The remaining 11 issues were validated and grouped and formalized into the 7 exhibits that follow:

IDSeverityAddressedTitle
AIK-01SIllegible Numeric Value Representation
AIK-02SInexistent Event Emission
BAI-01SIllegible Numeric Value Representation
BAI-02SInexistent Event Emission
BAS-01SIllegible Numeric Value Representations
BAS-02SInexistent Sanitization of Input Addresses
IPL-01SInexistent Sanitization of Input Address