Omniscia Tokemak Network Audit
Static Analysis
Static Analysis
The execution of our static analysis toolkit identified 237 potential issues within the codebase of which 192 were ruled out to be false positives or negligible findings.
The remaining 45 issues were validated and grouped and formalized into the 9 exhibits that follow:
ID | Severity | Addressed | Title |
---|---|---|---|
DRD-01S | Minor | Yes | Inexistent Zero-Address Check |
DRD-02S | Minor | Yes | Unused Return Value |
EPL-01S | Informational | No | Inexistent Event |
MAN-01S | Informational | Yes | Dead Code |
MAN-02S | Informational | Yes | Literal Boolean Comparison |
POO-01S | Informational | No | Inexistent Event |
RED-01S | Minor | Yes | Inexistent Zero-Address Check |
STA-01S | Minor | Yes | Inexistent Zero-Address Check |
TOK-01S | Informational | Yes | Illegible Numeric Literal |