Omniscia Moby Audit

Utils Static Analysis Findings

Utils Static Analysis Findings

USL-01S: Illegible Numeric Value Representation

TypeSeverityLocation
Code StyleUtils.sol:L20

Description:

The linked representation of a numeric literal is sub-optimally represented decreasing the legibility of the codebase.

Example:

contracts/Utils.sol
20int40 constant OFFSET19700101 = 2440588;

Recommendation:

To properly illustrate the value's purpose, we advise the following guidelines to be followed. For values meant to depict fractions with a base of 1e18, we advise fractions to be utilized directly (i.e. 1e17 becomes 0.1e18) as they are supported. For values meant to represent a percentage base, we advise each value to utilize the underscore (_) separator to discern the percentage decimal (i.e. 10000 becomes 100_00, 300 becomes 3_00 and so on). Finally, for large numeric values we simply advise the underscore character to be utilized again to represent them (i.e. 1000000 becomes 1_000_000).

Alleviation (a8720219a6a97e10b8d9c6a70c6345747f0fdcb3):

The referenced value literal has been updated in its representation to 2_440_588 in accordance with the recommendation's underscore style, addressing this exhibit.